Skip to content
default-logo
Get In Touch

Tool of the Month: Chloride Test Strips for feed uniformity test

  • Mohammad Afrouziyeh
  • July 6, 2023

Name: Chloride Quantab Test Strips 

Cost: $103 

Available at: Manufacturer’s website

Intended use

Chloride Quantab Test Strips have various industrial uses to measure chloride concentration in an aqueous sample. This article introduces the application of the strips in the feed mixture uniformity test. Multiple methods are employed in the feed industry to assess the consistency of mixtures. Among these, the prevalent ones involve chemical tests for minerals, amino acids, and chloride ion content. To accurately evaluate the uniformity of the mixture, it is important that the marker used originates from a single source, is approved for use in feed, and has a precise analysis method. Additionally, the marker should have an adequate number of particles per gram to ensure its detectability when obtaining a sample from the mixer. One of the common markers used in feed mills to assess feed uniformity is salt, which is used in diets from 0.2 to 0.5%. The salt’s particle size should be smaller than 400 microns when using a Chloride Quantab Test Strip to test the feed mixture uniformity.

Using the Chloride Quantab Test Strip to test feed uniformity

Take at least ten 100-g feed mixture samples from the different locations of a mixer, considering the sampling protocol explained in the previous article. Then follow the instructions below for each sample separately to measure chloride concentration:

  1. Using a 0.1-g readability scale, weigh a 10-g feed mixture sample into a cup and add 90 grams of hot distilled water to make an aqueous solution. 
  2. Stir the mixture for 30 seconds, let it sit for 60 seconds, and then stir it again for another 30 seconds.
  3. Filter the solution using a funnel and filter paper to eliminate suspended particles and transfer the solution into a test tube/cup.
  4. Insert a Chloride Quantab Test Strip into the liquid (Figure 1). Notice that the same lot of Chloride Quantab Test Strip should be used for all ten samples to obtain reliable, accurate results.
Figure 1. A Chloride Quantab Test Strip in a test solution at the beginning of the test. 
All Photos in this article are credited to the Government of Canada, Canadian Conservation Institute

5. After the column of the strip becomes fully saturated, an indicating band located horizontally at the top, which is sensitive to moisture, changes its color from yellow to black. This color transformation serves as a signal indicating the completion of the test (Figure 2).

Figure 2. Color change in the top horizontal completion band of the strip from yellow (left picture before exposure to a test solution) to black (right picture after completion of a test for chloride ions)

6. At the completion of the test, read the number at the top of the white peak (Figure 3)

Figure 3. Read the number at the top of the white peak. This picture shows a reading of 2.6 (consider that each gridline between 2 and 3 represents 0.2 increments)

7. Use the conversion charts on the back of the Chloride Quantab Test Strip bottle to convert strip reading to chloride ion percentage. The scales are unique for each batch of strips (Figure 4).

Figure 4. Conversion charts on the back of the Chloride Quantab Test Strip bottle to convert strip reading to chloride ion percentage.

8. Calculating the Coefficient of Variation (CV) from the results of 10 samples within a batch to determine mixing uniformity.

Example: Chloride ion concentration in 10 feed samples as follows: 0.31, 0.30, 0.35, 0.27, 0.31, 0.35, 0.25, 0.22, 0.35, 0.34. To find the tracer’s CV follow the following steps:

9. The interpretation of CV results was explained in our previous article. Briefly, a CV of less than 10% was considered as excellent uniformity, 10 to 15% as good uniformity, 15 to 20% as fair uniformity, and greater than 20% as poor uniformity by Herrman and Behnke (1994). However, the Guide to Feed Mixing protocol from the University of California, Davis suggests a 5% CV as the industry standard for most ingredients.

How does it work?

A Chloride Quantab Test Strip consists of a thin plastic strip with a capillary column impregnated with brown silver dichromate. After dipping the strip in the solution sample, the liquid enters through a small hole at the bottom of the column and then wicks up the column by capillary action. Chloride ions in the solution react with the silver dichromate, producing a white region of silver chloride on the column. The length of the white region can be converted to a chloride ion concentration using the calibration information supplied with the test strips. The test strips are available in two concentration ranges: 30 to 600 mg/L (30 to 600 parts per million [ppm]) and 300 to 6,000 mg/L (300 to 6,000 ppm).

References

Fahrenholz, A. 2019. Best practices: Mixing and sampling. Animal Feed Science and Technology. (Link)

Government of Canada. Test for Chloride Ions in Iron Treatment Solutions Using Quantab Test Strips – Canadian Conservation Institute (CCI) Notes 4/4. (Link)

Herrman, T. and K. Behnke. 1994. Testing mixer performance. MF1172. Kansas State University Agricultural Experiment Station and Cooperative Extension Service Bulletin, Manhattan, KS: Kansas State University (Link)

Stark, Ch., and Saensukjaroenphon M. 2017. Testing Mixer Performance. Kansas State University. (Link)

Zinn, R. A. 2020. A Guide to Feed Mixing. University of California, Davis. (Link)

Author Profile
Mohammad Afrouziyeh
Livestock Research Program Officer at RDAR - Results Driven Agriculture Research

Mohammad was the PIP team Research Associate (2021-2024) with extensive experience in poultry nutrition. He wrote science articles for newsletters and worked on developing adaptations and recommendations to support the adoption of new managerial tools, products, services, and practices by the poultry industry.

Looking at his poultry industry perspective, Mohammad has been serving the poultry industry through his extensive experience in feed formulation as an animal nutritionist over the past ten years. He was also a university lecturer for 10 years. Mohammad was a member of the Animal Care and Use Committee (ACUC) at the U of A. Mohammad graduated with a Ph.D. degree in Animal Science from the University of Alberta with a Postdoctoral fellowship before moving to his Research Associate position with the PIP team. Serving the poultry industry as an animal nutritionist for more than a decade, Mohammad loves teaching and worked as a university lecturer in Iran and a teaching assistant at the U of A. Mohammad was inspired by Dr. Frank Robinson, practicing the inquiry-based learning method when working as a TA in his “Principles of Animal Agriculture” class. “I have a strong passion on poultry nutrition and have always loved to help poultry producers with optimizing the poultry systems. The challenging part of working with live animals is that you need to be on call even as a nutritionist. However, the joy of seeing healthy animals and help with their welfare overcome the challenging part.”

Latest Posts
  • PIP Bids Farewell
  • Images from the 2025 Western Poultry Conference
  • Research Showcase - March Featured article
  • Western Poultry Conference 2025 – WPC Speaker and Event Wrap Up!
  • Western Poultry Conference 2025 Meet the Speaker: Dr. Carla Prado
Categories
cropped-eworx-logo.webp

©2025. eXtensionworX Canada Inc. All Rights Reserved.

ajax-loader
EXtensionWorX
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}
EXtensionWorX
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}